Best online tractor store info@agromastertraktor.com 0 506 604 34 21

GL6000 (5.5 KVA)

Description

Improved Reliability

  • Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
  • Large-capacity fuel tank (28L/7.4 U.S. gal.) enables longer continuous operation on a single tank.

Easy Maintenance

  • One-side maintenance to reduce the operator’s work load.
  • Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.

Safety Features

  • Protective covers on all moving parts (for the engine’s cooling fan and the generator).
  • Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.

Wide Application

  • Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
  • An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
MODEL Unit GL-6000
Type Rotating field single-phase AC generator
Frequency Hz 50
Standby Output kVA (kW) 6.0 (6.0)
Prime Output kVA (kW) 5.5 (5.5)
Voltage – Single Phase V 220
Armature Connection Series
Phase/Wire 1/2
Power Factor 1.0
No. of Poles 2
Insulation Class Rotor coil; class F, Stator coil; class B
Type of Coupling Direct coupled
AMPS
Single Phase 220V A 25.0
No. of Receptacles
5-20RA (GFCI) N/A
6-15R 2
L5-30R N/A
L6-30R N/A
L14-30R N/A
CS-6369 N/A
Terminal
Terminal Available
Diesel Engine
Type Vertical, liquid-cooled, 4-cycle diesel engine
Model Z482
No. of Cylinders 2
Bore x Stroke mm (in.) 67.0 x 68.0 (2.6 x 2.7)
Displacement L (cu. in.) 0.479 (29.2)
Engine Speed rpm 3000
Continuous Rated Output kW (HP) 6.9 (9.3)
Lubricant (API classification) Above CD grade
Oil Capacity L (qts.) 2.2 (0.58)
Coolant Capacity L (qts.) 3.7 (0.98)
SET
Fuel Consumption Diesel fuel No.2 (ASTM D975)
at Full Load L/h (gal./h) 2.2 (0.58)
at 3/4 Load L/h (gal./h) 1.8 (0.48)
at 1/2 Load L/h (gal./h) 1.5 (0.39)
at 1/4 Load L/h (gal./h) 1.2 (0.31)
Fuel Tank Capacity – Continuous Operation Hours L (gal.) 28.0 (7.4)
at Full Load h 12.0
at 3/4 Load h 15.6
at 1/2 Load h 18.7
at 1/4 Load h 23.3
Battery (Ah/5 h) 38B20R (12 V x 28 Ah)
Dimensions L x W x H mm (in.) 1066 x 618 x 698 (42.0 x 24.3 x 27.5)
Approx. Net Weight kg (lbs.) 235 (518)
Sound Level (Full Load at 23 ft. [7m]) dB (A) 65
Emergency Stop System In case of abnormal: Oil pressure, water temperature, or When the access terminal cover is opened
Price

Negotiable

GL Series

  • Prime Output 5.5 kVA (5.5 kW)
  • Standby Output 6.0 kVA (6.0 kW)
  • Frequency: 50 HZ
  • Phase: Single